国产aaaa级全身裸体精油片_337p人体粉嫩久久久红粉影视_一区中文字幕在线观看_国产亚洲精品一区二区_欧美裸体男粗大1609_午夜亚洲激情电影av_黄色小说入口_日本精品久久久久中文字幕_少妇思春三a级_亚洲视频自拍偷拍

IEC 61810-2-2017基礎(chǔ)機(jī)電繼電器--第2部分:可靠性Electromechanical elementary relays - Part 2: Reliability IEC 61810-2-2017基礎(chǔ)機(jī)電繼電器--第2部分:可靠性Electromechanical elementary relays - Part 2: Reliability

IEC 61810-2-2017基礎(chǔ)機(jī)電繼電器--第2部分:可靠性Electromechanical elementary relays - Part 2: Reliability

  • 標(biāo)準(zhǔn)類別:
  • 標(biāo)準(zhǔn)大?。?/li>
  • 標(biāo)準(zhǔn)編號(hào):IEC 61810-2-2017
  • 標(biāo)準(zhǔn)狀態(tài):現(xiàn)行
  • 更新時(shí)間:2023-04-21
  • 下載次數(shù):
標(biāo)準(zhǔn)簡(jiǎn)介

This part of IEC 61810 covers test conditions and provisions for the evaluation of endurance
tests using appropriate statistical methods to obtain reliability characteristics for relays.
This document applies to electromechanical elementary relays considered as non-repaired
items (i.e. items which are not repaired after failure).
The lifetime of a relay is usually expressed in number of cycles (CTF). Therefore, whenever
the terms “time” or “duration” are used in IEC 61649, they carry the meaning “cycles”.
However, with a given frequency of operation, the number of cycles can be transformed into
respective times (e.g. times to failure (TTF)).
The failure criteria and the resulting characteristics of elementary relays describing their
reliability in normal use are specified in this document. A relay failure occurs when the
specified failure criteria are met.
As the failure rate for elementary relays cannot be considered as constant, particularly due to
wear-out mechanisms, the cycles to failure of tested items typically show a Weibull
distribution. This document provides numerical and graphical methods to calculate
approximate values for the two-parameter Weibull distribution, as well as lower confidence
limits and a method for confirmation of reliability values with the WeiBayes method.
This document does not cover procedures for electromechanical elementary relays where
enhanced requirements for the verification of reliability apply.
NOTE 1 Such reliability test procedures are specified in IEC 61810-2-1. In particular, when electromechanical elementary relays are intended to be incorporated in safety-related control systems of machinery in accordance
with IEC 62061 and ISO 13849-1, IEC 61810-2-1 defines procedures for the manufacturer to provide B10D values.
NOTE 2 Electromechanical elementary relays with forcibly guided (mechanically linked) contacts according to IEC 61810-3 offer the possibility of a high diagnostic coverage according to 4.5.3 of ISO 13849-1:2015.dition 3.0 2017-05 INTERNATIONAL STANDARD NORME INTERNATIONALE colour inside Electromechanical elementary relays – Part 2: Reliability Relais électromécaniques élémentaires – Partie 2: Fiabilité IEC 61810-2:2017-05(en-fr) THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright ? 2017 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be repro

標(biāo)準(zhǔn)截圖